Standards:
Specification:
Our Walk-in Chamber use urethane-foam panels in a stainless steel or galvanized interior skin. This Walk-in Chamber is same construction used for walk-in coolers in restaurants, but of a higher quality.
Applications
Walk in test Chamber are used for various types of testing such as prototype evaluation, research & development testing, production testing, accelerated stress testing, reliability testing, failure analysis, and any other application where environmental simulation is needed.
Features
Walk-in, Drive-in Type
Stainless steel interior (or galvanized for savings)
Painted galvanized steel exterior for long life
MAP service doors are hinged (no tools or lifting)
Easy access to components
Reliable steam generator system for humidity applications
Sheathed electric heaters for safety and reliability
Adjustable vanes in supply grille allow directing of airflow as needed
Standards Implemented and met
GB-2423. 1-89(IEC68-2-1) Test A: Low Temperature Test
GB-2423. 2-89(IEC68-2-2) Test B: High Temperature Test
GJB360. 8-87(MIL-STD.202F) High Temperature Operating Life Test
GBJl50. 3(MIL-STD-810D) High Temperature Test
GJBl50. 4(MIL-STD-810D) Low Temperature Test
GB2423. 3-93(IEC68-2-3) Test Ca: method for steady-state damp heat test
GB2423. 4-93(IEC68-2—30) Test Db: Damp Heat Alternative Test
GJBl50. 9-93(MIL-STD-810D) Damp Heat Test
Specifications
High quality and reliability performance;
Controller:Touch screen, parameter and program control;
Competitive price and 12 months free parts warranty.
Model |
4 |
6 |
8 |
13 |
17 |
21 |
|
Interrior material (cm) |
W |
210 |
300 |
390 |
300 |
390 |
480 |
H |
210 |
210 |
210 |
210 |
210 |
210 |
|
D |
205 |
205 |
205 |
430 |
430 |
430 |
|
Volume(M3) |
9 |
12.9 |
16.8 |
16.8 |
35.2 |
13.3 |
|
Exterrior dimensions |
W |
325 |
416 |
505 |
505 |
505 |
595 |
H |
235 |
235 |
235 |
235 |
235 |
235 |
|
D |
225 |
225 |
225 |
225 |
450 |
450 |
|
System |
Balanced & Humidity Control Systerm |
||||||
Temp. range |
Maximum:80ºC,120ºC;Minimum:-60ºC,-50ºC,-40ºC,-30ºC,-20ºC,-10ºC,0ºC |
||||||
Humidity Range |
10%,20%,30%~95% |
||||||
Temp. constancy |
±0.5ºC |
||||||
Humidity constancy |
±2.5%R.H |
||||||
Temp. uniformity |
±2.0ºC |
||||||
Humidity uniformity |
±5.0%R.H |
||||||
Heat up time |
+20ºC~+80ºC ,Within 60 min |
||||||
Pull down time |
+20ºC~-55ºC -40ºC-20ºC-10ºC ,Within 120 or 90 or 60 or 45 min |
||||||
Interior material |
Stainless Steel Plate(SUS 304) |
||||||
Exterior material |
Baked Painting Steel Or Stainless steel(SUS304) |
||||||
Insulation material |
Rigid polyurethane foam |
||||||
Door size (mm) |
Single wing:W800*H1800;Double wing:W1600*H1800 |
||||||
Refrigeration system |
Semi-hermetic compressor, single stage or cascade refrigeration system,CFC free refrigerant(HFC-507 and HFC-23) |
||||||
Controllor |
Touch controller, Chinese menu, Operation mode: setting/program |
||||||
Safety Devices |
No fuse breaker, over pressureover heat and over current protection for compressor, over temperature protection, over load protection for blower, dry heat protection |
||||||
Standard accessories |
Sight window*1,cable port(portΦ50mm)*1,chamber lamp*1, status indicator |
||||||
Ambient Temp. |
+5ºC~+35ºC |
||||||
Power |
AC 380±10%50Hz ,3 phase 4 wires +Ground Wires |
||||||
Note:1. We reserve the right to change specifications without prior notice 2.Customized sizes and configurations available |